Product Description
Our offered CMS8000 Five Parameter Patient Monitor is a conventional equipment that is used in Arrhythmia analysis and S-T segment analysis. Owing to its technically sound design and user-friendly operations, it ensures a high level of accuracy. The device is the most suitable for the adult, pediatric and neonatal patient. It is equipped with a high definition seven-leads display. CMS8000 Five Parameter Patient Monitor is electrically operated and does not require frequent maintenance to function uninterruptedly for a long period of time.
Specification :
Features :
- 12.1" Colour TF T LCD display with waveforms upto 8 Channels
- Portable . streamline handle design
- Monitor measures from Adult to Neonates
- Graphic and tabular Trend for 96 hours for all parameters
- Multi Screen format
- Audible and Visual alarms with adjustable alarm ranges
- Powerful data management and storage capacity
- Manual or Automatic NIBP measuring with 500 unit memory
- Rechargeable battery backup
- Weight : 4.5Kg approx.
Respiration
- Method: RA-LL impedance
- Measurement range: Adult: 0-12orpm. Paediatric/neonatal 0-150mm
- Apnea alarm: YES
Temperature :
- Resolution: 0.1oC
- Channel: Dual-channel
- Measurement range: 0-50oC
IBP (Ungradable)
- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP. RAP, LAP. ICP
- Alarm range: -l0~300mmHg
ECG
- 5-lead or l2-lead selectable
- Input: S-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: l; I]; ill; avR; avL; avF; Vx; CAL
- Gain selection:x0.25, x0.5, x1, x2,auto
- Sweep speed: 12.5rnm/s, 25mm/s, 5omm/s
- Accuracy: +1bpm or +1%, whichever is greater
- Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: lmV +5%
- Operation modes: Diagnostic, Monitor, Surgery
- Heart rate range: Adult: 15-300bpm Pacdiatric/ Neonatal: 15- 350bpm
- Measurement range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
- Method: Oscillometiy
- Operation modes: Manual/Automatic."STAT
- Measurement unit: mmHg"KPa selectable
- Measurement types: Systolic, Diastolic. Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: l mmHg
- Accuracy : The mean error shall be less than +5 mmHg, the standard deviation shall be less than + 8 mmHg
- Alarm: Systolic, Diastolic, Mean
SpO2
- Measurement range: 0-100%
- Accuracy: +2%(70~100%); 0~69% unspecified
- Alarm range: 0-100%